AAP Elite S series Manuel d'utilisateur Page 22

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 32
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 21
22
USER FUNCTIONS
STARTING WALKTEST MODE
While in CLIENT mode a User with the proper authority can start walk-test
mode. This special mode latches the alarm signals from detectors at the
keypad initiating the test so that one person can trigger every detector
connected to the alarm then return to the keypad to verify operation. On
terminating Walk-test mode the test results are put into the memory buffer
so they can be viewed at a later time.
To start Walk-test mode while in CLIENT mode press;
<PROGRAM> <200> <ENTER> <6> <ENTER>
The keypad buzzer will beep at 1 second intervals
Next trigger every detector connected to the panel then return to the key-
pad and all of the zones that were triggered will be displayed at the key-
pad.
To terminate Walk-test mode press;
<ENTER>
The keypad will stop beeping and automatically exit CLIENT mode.
ANSWER AN IN-COMING CALL
From time to time your installer may need to access the alarm from a re-
mote PC to make changes to your programming and for security reasons
they may have configured the alarm so that an authorised person on-site
is required to make the alarm system answer the in-coming call. This func-
tion is available in Idle Mode (the panel is not armed or in program mode).
To answer an In-coming Call press;
<CONTROL> & <9>
(You must hold the “control button down and press 9 within 2 seconds)
Provided the line connected to the alarm was ringing at the time the panel
will now answer the call and allow a remote PC connection.